- Артикул:
- R855726
- виробник:
- Reichle & De-Massari
- наявнiсть:
- під замовлення
$4
R&M R855726 ВО кабель A-DQ(ZN)(SR)2Y 12xG652.D HDPE
Central loose tube cable, outdoor-use, CSTA - steel tape armour, HDPE sheath - black, 01x12-fibers G652.D
Описание R&M R855726 ВО кабель A-DQ(ZN)(SR)2Y 12xG652.D HDPE
Corrugated steel tape armoured central loose tube cable with excellent mechanical protection and thus secure rodent protected.
With up to 24 fibers maximum, suitable for outdoor duct or direct buried installation.
Technical Data R&M R855726 ВО кабель A-DQ(ZN)(SR)2Y
| DESCRIPTION | VALUE/VALUE RANGE |
|---|---|
| Cable type |
Central loose tube cable |
| Jacket material |
UV stable HDPE |
| CPR classification | Fca |
| Armour |
Corrugated steel tape armoured (CSTA) |
| Fiber type |
G.652.D |
| Fiber Count | 12 |
| Application |
outdoor-use |
| Cable family code | OX1ECH |
| DIN/VDE Code | A-DQ(ZN)(SR)2Y wbg |
| DoP no.: | D9911 |
| Loose-tube count | 1 |
| Fiber count per tube | 24 |
| Loose tube nominal diameter [mm] | 3 mm |
| Outer jacket nominal thickness [mm] | 1.2 mm |
| Cable outer diameter [mm] | 7.7 mm |
| Cable version |
n.a. |
| Standard put-up length on drum | 2100 m ± 5% |
| Maximum length on drum | 4100 m ± 5% |
| RoHS |
Pass |
Mechanical Data R&M R855726 ВО кабель A-DQ(ZN)(SR)2Y
| DESCRIPTION | VALUE/VALUE RANGE |
|---|---|
| Cable weight | 70.0 kg/km / 47 lbs/1000ft |
| Tensile performance - in service |
500 N |
| Tensile performance - in service test method |
IEC 60794-1-21:E1 |
| Tensile performance - in service acceptance criteria |
Δα ≤ 0,05 dB |
| Tensile performance - during installation |
1500 N |
| Tensile Performance during Installation TestMethod |
IEC 60794-1-21:E1 |
| Tensile performance - during installation acceptance criteria |
Δα ≤ 0,05 dB after test |
| Crush resistance - long term |
2500 N/100mm |
| Crush resistance - long term test method |
IEC 60794-1-21:E3A |
| Crush resistance - long term acceptance criteria |
Δα ≤ 0,05 dB prior release, no damage |
| Impact resistance |
20 Nm, 3 impacts, d=20 mm, R=300 mm |
| Impact resistance test method |
IEC 60794-1-21:E4 |
| Impact resistance acceptance criteria |
Δα ≤ 0,05 dB after test, no damage |
| Torsion |
L = 1 m, rotation angle ±180°, 10 cycles |
| Torsion test method |
IEC 60794-1-21:E7 |
| Torsion acceptance criteria |
no damage |
| Cable bend |
d=20 x cable diameter, 4 turns, 3 cycles |
| Cable bend - test method |
IEC 60794-1-21:E11A |
| Cable bend - acceptance criteria |
Δα ≤ 0,05 dB after test, no damage |
| Repeated bending |
R=20 x cable diameter, 25 cycles |
| Repeated bending test method |
IEC 60794-1-21:E6 |
| Repeated bending acceptance criteria |
no damage |
Climatic Data R&M R855726 ВО кабель A-DQ(ZN)(SR)2Y
| DESCRIPTION | VALUE/VALUE RANGE |
|---|---|
| Temperature cycling | -20 °C +70 °C / -4 °F +158 °F |
| Temperature cycling - reversible | -30 °C +70 °C / -22 °F +158 °F |
| Installation temperature | -5 °C +50 °C / +23 °F +122 °F |
| Operation temperature | -20 °C to +70 °C / -4 °F to +158 °F |
| Transport / store temperature | -30 °C to +70 °C / -22 °F to +158 °F |
Оставьте свой отзыв о данной продукции и